YUYUE outdoor integrated telecom cabinet is an integrated outdoor equipment enclosure developed for global 4G/5G macro base stations, micro base stations and edge access sites. It integrates wireless main equipment, AC/DC power distribution, rectifier power supply, batteries, temperature control & heat dissipation, environmental monitoring, lightning protection, fire suppression and other systems into a single cabinet in the factory. No auxiliary equipment room is required, and the cabinet can be directly installed on the ground, pole or rooftop. It adapts to various site conditions without equipment rooms worldwide, such as remote areas, urban districts, coastal zones and deserts, serving as a core carrier for lightweight and rapid deployment of communication infrastructure.
According to diverse customer demands and regional environmental requirements, our Outdoor Integrated Telecom Cabinets are available in three structural types:
1.Single-layer sheet metal cabinet lined with PEF thermal insulation cotton inside
2.EPS/PU sandwich panel structure
3.Double-layer sheet metal cabinet with PEF thermal insulation cotton sandwiched in between
Outdoor telecom cabinets are equipped with cabinet air conditioners, heat exchangers or cooling fans as heat dissipation solutions. These solutions effectively maintain the optimal operating temperature of internal equipment and extend the service life of electronic devices.
Reference of Mainstream Specifications
1.Small pole-mounted cabinet: 10U–14U, for urban micro base stations
2.Floor-standing single-compartment cabinet: 18U–42U, for township macro base stations
3.Large-capacity dual/multi-compartment integrated cabinet: 40U–120U, for high-density 5G main base stations
4.Custom special models: Anti-corrosion stainless steel cabinets, photovoltaic integrated energy storage telecom cabinets, low-temperature heating cabinets for Nordic regions
Technical Specifications
Technical Parameters
| Product name | Vertical Split Outdoor Telecom Cabinet |
Model | YY-220007500750-A | |
Dimension(HxWxD) | 2200×750×750mm | |
Material | Galvanized sheet | |
Insulation thickness | 20mm thick PEF insulation cotton | |
Maintenance method | Front opening door | |
Assembling method | Floor | |
Rack size | 19 inch rack+8 pairs of L-shaped support bars | |
Protection level | IP55 | |
Working temperature | -40℃~+55℃ | |
Cool system | Power Compartment: 150W/K 48VDC heat exchanger Battery Compartment: 300W cooling 48VDC cabinet air conditioner |